Purchase Franklin Electric Control Box Parts 1-866-960-9621.


Franklin Control Box Parts




Table 48  QD Control Box Parts 60 Hz
HP Volts Control Box Model Number QD (Blue) Relay Start Capacitor MFD Volts Run Capacitor MFD Volts
1/3 115 280 102 4915 223 415 905 275 464 125 159-191 110      
230 280 103 4915 223 415 901 275 464 126 43-53 220
1/2 115 280 104 4915 223 415 906 275 464 201 250-300 125 156 132 101 15 370
230 280 105 4915 223 415 902 275 464 105 59-71 220
230 282 405 5015 (CRC) 223 415 912 275 464 126 43-53 220
3/4 230 280 107 4915 223 415 903 275 464 118 86-103 220 156 132 102 23 370
230 282 407 5015 (CRC) 223 415 913 275 464 105 59-71 220
1 230 280 108 4915 223 415 904 275 464 113 105-126 220 156 132 102 23 370
230 282 408 5015 (CRC) 223 415 914 275 464 118 86-103 220
 
Table 49  Integral Horsepower Control Box Parts 60Hz
Motor Size Motor Rating HP

Control Box (1)
Model No.

Capacitors Overload (2) Part No. Relay (3) Part No. Contactor (2) Part No.
Part No. (2) Mfd. Volts Qty.
4" 1-1 1/2 Standard 282 3008 110 275 464 113 S 105-126 220 1 275 411 107 155 031 102  
155 328 102 R 10 370 1
282 300 8610 275 464 113 S 105-126 220 1 None
(See Note 4)
155 031 102  
155 328 101 R 15 370 1
4" 2 Standard 282 3018 110 275 464 113 S 105-126 220 1

275 411 107 S

275 411 113 M

155 031 102  
155 328 103 R 20 370 1
4" 2
Deluxe
282 3018 310 275 464 113 S 105-126 220 1

275 411 107 S

275 411 113 M

155 031 102 155 325 102 L
155 328 103 R 20 370 1
4" 3
Standard
282 3028 110 275 463 111 S 208-250 220 1

275 411 108 S

275 411 115 M

155 031 102  
155 327 109 R 45 370 1
4" 3
Deluxe
282 3028 310 275 463 111 S 208-250 220 1

275 411 108 S

275 411 115 M

155 031 102 155 325 102 L
155 327 109 R 45 370 1
4" & 6" 5
Standard
282 1138 110 275 468 119 S 270-324 330 1

275 411 102 S

275 406 102 M

155 031 601  
155 327 114 R 40 370 2
4" & 6" 5
Deluxe
282 1138 310 or
282 1139 310
275 468 119 S 270-324 330 1

275 411 102 S

275 406 102 M

155 031 601 155 326 101 L
155 327 114 R 40 370 2
6" 7 1/2
Standard
282 2019 210 275 468 119 S 270-324 330 1

275 411 102 S

275406 122 M

155 031 601  
275 468 118 S 216-259 330 1
155 327 109 R 45 370 1
6" 7 1/2
Deluxe
282 2019 310 275 468 119 S 270-324 330 1 275 411 102 S

275 406 121 M
155 031 601 155 326 102 L
275 468 118 S 216-259 330 1
155 327 109 R 45 370 1
6" 10
Standard
282 2029 210 275 468 119 S 270-324 330 1

275 406 103 S

 

155 409 101 M

155 031 601  
275 468 120 S 350-420 330 1
155 327 102 R 35 370 2
6" 10
Standard
282 2029 230 275 463 120 S 130-154 330 1

275 406 103 S

 

155 409 101 M

155 031 601  
275 468 118 S 216-259 330 1
275 468 119 S 270-324 330 1
155 327 102 R 35 370 2
6" 10
Deluxe
282 2029 310 275 468 119 S 270-324 330 1

275 406 103 S

155 409 101 M

155 031 601 155 326 102 L
275 468 120 S 350-420 330 1
155 327 102 R 35 370 2
6" 10
Deluxe
282 2029 330 275 463 120 S 130-154 330 1

275 406 103 S

 

155 409 101 M

155 031 601 155 326 102 L
275 468 118 S 216-259 330 1
275 468 119 S 270-324 330 1
155 327 102 R 35 370 2
6" 15
Deluxe
282 2039 310 275 468 120 S 350-420 330 2

275 406 103 S

155 409 102 M

155 031 601 155 429 101 L
155 327 109 R 45 370 3
6" 15
Deluxe
282 2039 330 275 463 122 S 161-193 330 3

275 406 103 S

155 409 102 M

155 031 601 155 429 101 L
155 327 109 R 45 370 3
6" 15
X-Large
282 2039 621 275 468 120 S 350-420 330 2

275 406 103 S

155 409 102 M

155 031 601

2 Required
155 429 101 L
155 327 109 R 45 370 3
 

FOOTNOTES:

  1. Lightning arrestors 150 814 902 are suitable for all control boxes.

  2. S = Start, M = Main, L = Line, R = Run
    Deluxe = Control box with line contactor.

  3. For 208 V systems or where line voltage is between 200 V and 210 V, a low voltage relay is required. On 3HP and smaller control boxes use relay part 155 031 103 in place of 155 031 102 and use the next larger cable size than specified in 230 V table. On 5 hp and larger use relay 155 031 602 in place of 155 031 601 and next larger wire. Boost transformers per page 15 are an alternative to special relays and cable.

  4. Control box model 282 300 8610 is designed for use with motors having internal overload protectors. If used with a 1.5 hp motor manufactured prior to date code 06H18, Overload/Capacitor Kit 305 388 901 is required.
NOTE 1:  
Control boxes supplied with QD Relays are designed to operate on 230 volt systems. For 208 volt systems or where line voltage is between 200 volts and 210 volts use the next larger cable size, or use a boost transformer to raise the voltage.
 
QD Capacitor Replacement Kits
Capacitor Number Kit
275 464 105 305 207 905
275 464 113 305 207 913
275 464 118 305 207 918
275 464 125 305 207 925
275 464 126 305 207 926
275 464 201 305 207 951
156 362 101 305 203 907
156 362 102 305 203 908
NOTE 2:  
Voltage relays kits for 115 volts (305102901) and 230 volts (305102902) will replace current, voltage or QD Relays, and solid state switches.
 
 
Overload Kits 60 Hz
HP Volts Kit (1)
1/3 115 305100 901
1/3 230 305100 902
1/2 115 305100 903
1/2 230 305100 904
3/4 230 305100 905
1 230 305100 906
  1. For Control Boxes with model
    numbers that end with 915
 
QD Relay Replacement Kits
QD Relay Number Kit
223 415 901 305 101 901
223 415 902 305 101 902
223 415 903 305 101 903
223 415 904 305 101 904
223 415 905 305 101 905
223 415 906 305 101 906
223 415 912 (CRC) 305 105 901
223 415 913 (CRC) 305 105 902
223 415 914 (CRC) 305 105 903