Single Phase- 3 Wire- Submersible Motor
Franklin Control Boxes
![]() |
Years of experience in designing and manufacturing our own motors mean that we also know how to protect them. Franklin’s single- and three-phase protective devices have been exclusively designed to help extend the life of Franklin motors. They monitor and diagnose motor load to prevent pump or motor failure due to adverse conditions such as low-flow wells, pump damage, clogging, bound pump, or power mishaps.
Single-Phase: Pumptec, QD Pumptec, Pumptec-Plus
Three-Phase: SubMonitor
|
Applications
QD & CRC - These control boxes are designed for use with Franklin 3-wire single-phase submersible motors through 1 hp.
STANDARD & DELUXE - These control boxes are designed for use with Franklin 3-wire single-phase submersible motors from 1 through 15 hp. Recommended for water systems that use standard/heavy-duty pressure switches, level switches or other pilot devices. Deluxe boxes (only) contain magnetic line contactors carefully matched to the motor rating, eliminating the need for external line contractors.
Basic Features – All Boxes
- Suitable for outdoor mounting
- Capacitor start / capacitor run design (except QD boxes)
- UL 778 recognized and CSA certified for 60 Hz models
Basic Features – Standard & Deluxe Boxes
- Heavy duty box-type terminals accept up to AWG #2 wire
- External access to overload resets
- Multiple-size knockouts
- User-friendly connection diagrams
- Easy access to grounding lugs
"You may find it somewhere else for less but less always requires a sacrifice"
|
FedEx Express Shipping Available
Check shipping time from 33966 |
Note: We deduct $20 for upgraded shipping.
|
Call Toll Free - 1-866-960-9621 for FedEx Express Shipments.
Motor and Control Box Hook Up
| Description | Type | HP | Volts | HZ | MODEL NO. | Self Installer Value Price |
| 4" 3W CB & Acc | CONTROL BOX, QD | 1/3 | 115 | 60 | 2801024915 | |
| 4" 3W CB & Acc | CONTROL BOX, QD | 1/3 | 230 | 60 | 2801034915 | |
| 4" 3W CB & Acc | CONTROL BOX, QD | 1/2 | 115 | 60 | 2801044915 | |
| 4" 3W CB & Acc | CONTROL BOX, QD | 1/2 | 230 | 60 | 2801054915 | |
| 4" 3W CB & Acc |
CONTROL BOX, CRC add performance lower power consumption |
1/2 | 230 | 60 | 2824055015 | |
| 4" 3W CB & Acc | CONTROL BOX, QD | 3/4 | 230 | 60 | 2801074915 | |
| 4" 3W CB & Acc | CONTROL BOX, CRC
add performance lower power consumption |
3/4 | 230 | 60 | 2824075015 | |
| 4" 3W CB & Acc | CONTROL BOX, QD | 1 | 230 | 60 | 2801084915 | |
| 4" 3W CB & Acc | CONTROL BOX, CRC
add performance lower power consumption |
1 | 230 | 60 | 2824085015 | |
| 4" 3W CB & Acc | CONTROL BOX,
STANDARD W/OVERLOAD VIEW CAUTION NOTE; for protection on motors built prior to Aug. 1, 2006 |
1.5 | 230 | 60 | 2823008110 w/overload | |
| 4" 3W CB & Acc | CONTROL BOX,
STANDARD WITHOUT OVERLOAD VIEW CAUTION NOTE; for protection on motors built after to Aug. 1, 2006 |
1.5 | 230 | 60 | 2823008610 less overload | |
| 4" 3W CB & Acc | CONTROL BOX, STANDARD | 2 | 230 | 60 | 2823018110 | |
| 4" 3W CB & Acc | CONTROL BOX, DELUXE | 2 | 230 | 60 | 2823018310 | |
| 4" 3W CB & Acc | CONTROL BOX, STANDARD | 3 | 230 | 60 | 2823028110 | |
| 4" 3W CB & Acc | CONTROL BOX, DELUXE | 3 | 230 | 60 | 2823028310 | |
| 4" 3W CB & Acc | CONTROL BOX, STANDARD | 5 | 230 | 60 | 2821138110 | |
| 4" 3W CB & Acc | CONTROL BOX, DELUXE | 5 | 230 | 60 | 2821139310 | |
| 6" 1P CB & Acc | CONTROL BOX, STANDARD | 7.5 | 230 | 60 | 2822019210 | |
| 6" 1P CB & Acc | CONTROL BOX, DELUXE | 7.5 | 230 | 60 | 2822019310 | |
| 6" 1P CB & Acc | CONTROL BOX, STANDARD | 10 | 230 | 60 | 2822029230 | |
| 6" 1P CB & Acc | CONTROL BOX, DELUXE | 10 | 230 | 60 | 2822029330 | |
| 6" 1P CB & Acc | CONTROL BOX, DELUXE | 15 | 230 | 60 | 2822039330 | |
| 6" 1P CB & Acc | CONTROL BOX, DELUXE - XL | 15 | 230 | 60 | 2822039621 |
There is a FL State Sales Tax that applies only to Florida residents without a resale certificate.
Standard Control Box Dimensions
|
![]() |
Deluxe Control Boxes
|
|
Quick-Disconnect (QD) Control Boxes
|
![]() |
Capacitor Run Control (CRC) Boxes
(a run capacitor adds pump performance and lowers power consumption)
|
![]() |
Valuable Information
3-Wire Control Boxes
Single-phase three-wire submersible motors require the use of control boxes. Operation of motors without control boxes or with incorrect boxes can result in motor failure and voids warranty. Control boxes contain starting capacitors, a starting relay, and, in some sizes, overload protectors, running capacitors and contactors. Ratings through 1 hp may use either a Franklin Electric solid state QD or a potential (voltage) type starting relay, while larger ratings use potential relays. Potential (Voltage) Relays: Potential relays have normally closed contacts. When power is applied, both start and main motor windings are energized, and the motor starts. At this instant, the voltage across the start winding is relatively low and not enough to open the contacts of the relay. As the motor accelerates, the increasing voltage across the start winding (and the relay coil) opens the relay contacts. This opens the starting circuit and the motor continues to run on the main winding alone, or the main plus run capacitor circuit. After the motor is started the relay contacts remain open.
CAUTION: The control box and motor are two pieces of one assembly. Be certain that the control box and motor hp and voltage match. Since a motor is designed to operate with a control box from the same manufacturer, we can promise warranty coverage only when a Franklin control box is used with a Franklin motor.2-Wire Motor Solid State Controls
BIAC Switch OperationWhen power is applied the bi-metal switch contacts are closed, so the triac is conducting and energizes the start winding. As rpm increases, the voltage in the sensor coil generates heat in the bi-metal strip, causing the bi-metal strip to bend and open the switch circuit. This removes the starting winding and the motor continues to run on the main winding alone. Approximately 5 seconds after power is removed from the motor, the bi-metal strip cools sufficiently to return to its closed position and the motor is ready for the next start cycle.
Rapid CyclingThe BIAC starting switch will reset within approximately 5 seconds after the motor is stopped. If an attempt is made to restart the motor before the starting switch has reset, the motor may not start; however, there will be current in the main winding until the overload protector interrupts the circuit. The time for the protector to reset is longer than the reset of the starting switch. Therefore, the start switch will have closed and the motor will operate. A waterlogged tank will cause fast cycling. When a waterlogged condition does occur, the user will be alerted to the problem during the off time (overload reset time) since the pressure will drop drastically. When the waterlogged tank condition is detected, the condition should be corrected to prevent nuisance tripping of the overload protector.
Bound Pump (Sandlocked)When the motor is not free to turn, as with a sandlocked pump, the BIAC switch creates a “reverse impact torque” in the motor in either direction. When the sand is dislodged, the motor will start and operate in the correct direction.
QD Relays (Solid State)
There are two elements in the relay: a reed switch and a triac. The reed switch consists of two tiny rectangular blade-type contacts, which bend under magnetic flux. It is hermetically sealed in glass and is located within a coil, which conducts line current. When power is supplied to the control box, the main winding current passing through the coil immediately closes the reed switch contacts. This turns on the triac, which supplies voltage to the start winding, thus starting the motor. Once the motor is started, the operation of the QD relay is an interaction between the triac, the reed switch and the motor windings. The solid state switch senses motor speed through the changing phase relationship between start winding current and line current. As the motor approaches running speed, the phase angle between the start current and the line current becomes nearly in phase. At this point, the reed switch contacts open, turning off the triac. This removes voltage from the start winding and the motor continues to run on the main winding only. With the reed switch contacts open and the triac turned off, the QD relay is ready for the next starting cycle.